BJRJP - PR-1141, PART B

Product Identification

Product ID:PR-1141, PART B
MSDS Date:03/27/1989
FSC:8010
NIIN:00N011150
Kit Part:Y
MSDS Number: BJRJP

Responsible Party
PRODUCTS RESEARCH & CHEMICAL CORPORATION
5430 SAN FERNANDO ROAD
GLENDALE, CA 91209
US

Emergency Phone: 800-228-5635; 818-240-2060

Info Phone: 818-240-2060

Cage: DO563

Contractor
PRODUCTS RESEARCH & CHEMICAL
1800 GLENDALE, CA 91209 US

Telephone: 818-240-2060

Cage: DO563

Ingredients

METHYL N-AMYL KETONE

CAS: 110-43-0

RTECS: MJ5075000

Fraction By Weight: 40%

OSHA PEL 100 PPM

ACGIH TLV: 50 PPM; 9192


POLYURETHANE PREPOLYMER

CAS: 59330-00-6

Fraction By Weight: 30%


METHYLENE BIS(4-CYCLOHEXYLISOCYANATE)

CAS: 5124-30-1

RTECS: NQ9250000

OSHA PEL C, 0.01 PPM

ACGIH TLV: 0.005 PPM; 9192


POLYURETHANE PREPOLYMER

CAS: 55636-48-1

Fraction By Weight: 30%


ISOPHORONE DIISOCYANATE (SARA III)

CAS: 4098-71-9

RTECS: NQ9370000

OSHA PEL S 0.005PPM/0.02STEL

ACGIH TLV: 0.005 PPM; 9394


ON EQUIPMENT AND AREA SURFACES UNTIL

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES:VAPS WILL CAUSE IRRI W/WATERING
OF EYES.LIQ CONT WILL CAUSE IRRI & POSS PERM DMG.SKIN:LOC
SWELL,SORENESS,ITCHNG,IN SENSITIZED INDIVIDUALS,EXPOS TO LIQ/VAPS
WILL RESULT IN AN ALLERGIC SKIN RASH.IN HAL:IRRI OF NOSE, THROAT &
EYES. BRONCHIRRIT W/COUGHING, TIGHTNESS IN CHEST & POSS DIFF IN
BRTHG.(SEE EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:MAY PRODUCE ASTHMA-LIKE SYMPTOMS IN
SENSITIZED INDIVIDUALS. INDIVIDUALS SUFFERING FROM ASTHMA OR OTHER
CHRONIC RESPIRATORY CONDITIONS MAY EXHIBIT A HEIGHTENED SENSITIVITY
TO ISOCYANATES AND S HOULD AVOID INHALATION EXPOSURE.
INGEST:IRRITATION OF DIGESTIVE TRACT AND STOMACH.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES:FLUSH WITH LUKE WARM WATER FOR 15 MINUTES. IF SYMPTOMS
PERSIST, CONSULT PHYSICIAN. SKIN:WASH WITH SOAP AND WATER. IF
SYMPTOMS PERSIST, CONSULT A PHYSICIAN. INHAL:REMOVE TO FRESH AIR.
IF SYMPTOMS ARE PRESENT CONSULT A PHYSICIAN. INGEST:CONSULT A
PHYSICIAN.

Fire Fighting

Flash Point Method:PMCC
Flash Point:102F,39C
Lower Limits:1.1
Upper Limits:7.9% (MAK)
Extinguishing Media:CO*2, DRY CHEMICAL, FOAM, WATER FOG.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT. USE WATER TO COOL HEAT EXPOSED CONTAINERS.
Unusual Fire/Explosion Hazard:HIGH TEMPERATURES MAY CAUSE PRESSURE
BUILDUP IN CLOSED CONTAINERS.

Accidental Release

Spill Release Procedures:REMOVE ALL IGNIT SOURCES. WEAR AIR-SUPPLIED
RESP FOR MAJOR UNVENT SPILL. COVER W/ABSORB MATL, ADD
DECONTAMINATED SOLN & ALLOW TO REACT FOR 10 MIN. COLLECT IN CNTNRS,
ADD ADDL DECONTAMINATION SOLN & KE EP LOOSELY COVERED FOR 48 HOURS.
Neutralizing Agent:DECON SOLN:5% CONC AMMONIA, 2% DETERGENT, 93% WATER.

Handling

Handling and Storage Precautions:AVOID MOISTURE CONTAMINATION. DO NOT
RESEAL CONTAINERS IF MOISTURE CONTAMINATION IS SUSPECTED.
Other Precautions:THE SPRAY APPLICATION SHOULD BE ISOLATED TO REDUCE
THE POTENTIAL FOR EXPOSURE. IN OPEN AREAS, AT LEAST 100 FEET SHOULD
SEPARATE THIS OPERATION FROM ANY PERSONS NOT PROTECTED. INSIDE
SPRAY APPLICATIONS SHOULD BE IN AN AREA (SEE SUPP DATA)

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED AIR-SUPPLIED RESPIRATOR IN
CONFINED AREAS OR WHEN PEL EXCEEDED.
Ventilation:GENERAL VENT TO MAINTAIN VAPORS BELOW PEL/TLV. (REFER TO
OTHER PRECAUTIONS).
Protective Gloves:SOLVENT RESISTANT GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:DURING SPRAY APPLICATION, STRINGENT
PRECAUTIONS MUST BE TAKEN TO ENSURE SAFETY OF THE PERSONS INVOLVED
WITH APPLICATION.
Work Hygienic Practices:WHEN APPLYING BY SPRAY USE FULL IMPERMEABLE
PROTECTIVE SUIT W/HEAD COVERING, FACESHIELD, GLOVES AND OVERSHOES.
Supplemental Safety and Health
OTHER PREC:SEPARATED FROM OTHER WORK AREAS BY WALLS & VENT BY LOCAL
VENT, PROPERLY DESIGNED & OPERATED IN ACCORDANCE W/ACGIH GUIDELINES
AS CONTAINED IN INDUSTRIAL VENT PUBLICATION OR OTHER APPROP COLL
ECTION SYS TO COLLECT ANY OVERSPRAY. UNPROTECTED PERSONS MUST BE
PVNTD FROM CONTACTING UNCURED RESIDUE (SEE INGRED 6)

Chemical Properties

Vapor Density:3.94 (MAK)
Spec Gravity:0.96
Evaporation Rate & Reference:0.4 (MAK)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.

Stability

Stability Indicator/Materials to Avoid:YES
WATER, ALCOHOLS, STRONG BASES, AMINES. STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:OXIDES OF CARBON.

Disposal

Waste Disposal Methods:EPA WASTE NO. D-001. DISPOSE OF SPILLAGE IN
COMPLIANCE WITH FEDERAL AND STATE REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.